Commit Graph
5 Commits
Author SHA1 Message Date
stroblme 7a7315043d Alerts: a delivery no channel took leaves the cooldown unspent 2026-11-01 10:59:28 +01:00
Melvin Strobl 72c1d73e96 Camera permission and review fixes (openpanel C3, C4)
C4: a device's `viewers` (superusers by default, or members) covers the
image and video messages its ports publish. Anyone else gets none of their
values on the socket, in the catalogue or a flow's state, 403 for their
history, for the frames they hold (the last 8 included) and for TURN
credentials, no bytes when asking for them, and `bye: forbidden` for a live
view. A device credential stays bounded by its dashboards. The device page
sets it in its Camera section, and a tile the viewer may not see says
"No access to this camera" and asks the camera for nothing.

C3:
- A volatile upload is held to MAX_FRAME_BYTES (4 MiB, 413 above it, read
  without extra copies), and so is a frame on a device's socket.
- A frame the engine holds in memory is written to the ring directory
  before a local worker is handed it, so load_artifact finds it.
- A socket the bus dropped events for catches up with a snapshot, demand
  included, and a device's credential is checked again per frame, cached by
  the flow store revision and its nonce, so a lost event never keeps an
  unpaired device's frames coming.
- A report is at most 64 KB once its named config_schemas are put in place.
- A device away for 60 s has its true bool messages set to false.
- Refused frames are logged by fixed keys, a frame is named after its
  message, `fluksio serve` waits 5 s for open connections, a tile with a
  stream URL creates no demand, the 8-name cap keeps the newest names.
- Every container's log rotates (json-file, 3 x 10 MB).
2026-10-17 09:20:04 +02:00
Melvin Strobl 13d23f6baf Restart safety: transient credential checks are 1013/503, not a refusal
- A device credential that cannot be checked now (device store not running,
  nonces unreadable) raises DeviceUnavailable: 503 over HTTP, and the
  /flows/ws handshake and the tunnel stream accept and close with 1013.
  1008 (a 403 before accepting) stays for a revoked or invalid one
- Device files are written through a temporary file, so a read mid-save no
  longer looks like a deleted device
- The first report turns Touch friendly on only for a device paired since
  pairings are noted (DeviceState.paired_at), so devices paired before keep
  the switch they were given
- NodeDef reads `device`/`device_policy` from older clients as the worker
  label, for a release
- Tests: transient vs revoked socket, the touch default, the old worker keys,
  and a restart with a device node and a node_health rule sending no push
2026-10-16 18:18:42 +02:00
Melvin Strobl 4286acadfd Capability report: PUT /devices/{id}/report, a Capabilities section, offline devices degraded
A device reports its board, screen, camera and ports from its own
credential (16 KB, schema 1, replacing the last report), and the flows
are validated against it again. The node panel turns a reported port's
config schema into a form, a reported screen is a canvas preset and a
touch screen's first report turns Touch friendly on. An offline device
node is degraded: amber on the canvas, a warning on Home, never a fault.
2026-10-16 17:37:49 +02:00
Melvin Strobl 29d3ec467f Device node: a device's ports are wired in flows
- flow/nodes/device.py: `device` node with params `device` and `config`;
  provides the device's `in` ports, requires its `out` ports without
  waking anything, never run (Node.passive), down "Offline" from presence
- DeviceDef.io and DevicePort go; GET /devices/{id} computes `io` and
  `bindings` from the device nodes of published flows, in a fixed order,
  cached by FlowStore.revision; the credential's scope comes from them
- issues `unknown_device` and `device_port` (wired twice; against a report
  the wrong direction or dtype, or unlisted as advisory), rechecked when a
  device is created or deleted; ValidationIssue.advisory is a field
- a device publishing on a bound port is credited to its node by the
  server; the panel endpoint kind is gone from `_endpoints` and the canvas
- a rebuild that moves a device's bindings sends `dashboard_changed` with
  an empty name, which the firmware refetches on
- startup moves each device's `io` rows into device nodes in the flows
  declaring their messages, draft and published, one commit; rows no
  flow declares are logged and left out
- frontend: Device node settings (device, Publishes, Follows, a port
  picker from a report), palette shortcuts per reported port, DeviceDetail
  lists bindings with "Use in flow" in place of the I/O editor
- docs: devices, flow editor, node types, issues, API
2026-10-16 16:40:31 +02:00