- flow/nodes/device.py: `device` node with params `device` and `config`;
provides the device's `in` ports, requires its `out` ports without
waking anything, never run (Node.passive), down "Offline" from presence
- DeviceDef.io and DevicePort go; GET /devices/{id} computes `io` and
`bindings` from the device nodes of published flows, in a fixed order,
cached by FlowStore.revision; the credential's scope comes from them
- issues `unknown_device` and `device_port` (wired twice; against a report
the wrong direction or dtype, or unlisted as advisory), rechecked when a
device is created or deleted; ValidationIssue.advisory is a field
- a device publishing on a bound port is credited to its node by the
server; the panel endpoint kind is gone from `_endpoints` and the canvas
- a rebuild that moves a device's bindings sends `dashboard_changed` with
an empty name, which the firmware refetches on
- startup moves each device's `io` rows into device nodes in the flows
declaring their messages, draft and published, one commit; rows no
flow declares are logged and left out
- frontend: Device node settings (device, Publishes, Follows, a port
picker from a report), palette shortcuts per reported port, DeviceDetail
lists bindings with "Use in flow" in place of the I/O editor
- docs: devices, flow editor, node types, issues, API
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- flow/devices.py: DeviceDef in FLOWS_DIR/_devices/<id>.json, committed under
the flow store's write lock, 409 on a stale version; nonces in DEVICES_FILE
outside git; in-memory presence announced as device_status
- api/routes/devices.py: CRUD, pairing with an optional {name, board,
firmware}, a pending list adopted without a code from the LAN only, unpair;
/panels/pair, /panels/pair/{code} and GET /panels/{id} kept as aliases,
PUT /panels/ gone
- _device_may replaces _panel_may, JWT claims unchanged
- panels.json moves into devices once at startup, then .migrated
- MCP list_devices, get_device; search category device
- Devices tab (list, detail with presence, pairing, ordered dashboards,
touch, I/O), PanelsDialog removed, serialised optimistic saves
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- A node's height follows the ports on its busiest side. It is a function of
the document, so `layoutGraph` reserves exactly what is drawn and nothing
measured is fed back into the layout.
- The three status controls now sit in slots that are there whether the
control is or not. A node running many times a second mounted and unmounted
the stop button on every execution, resizing the card each time.
- A port bound to another flow's message is drawn as a label, naming the node
at the far end and its type. Only the opposite direction was answered
before. The scan behind both is now cached on the store's commit counter
rather than reading every flow per request.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016ZeGnqVsf5VHQqvz4HdUhN