Commit Graph
3 Commits
Author SHA1 Message Date
Melvin Strobl 72c1d73e96 Camera permission and review fixes (openpanel C3, C4)
C4: a device's `viewers` (superusers by default, or members) covers the
image and video messages its ports publish. Anyone else gets none of their
values on the socket, in the catalogue or a flow's state, 403 for their
history, for the frames they hold (the last 8 included) and for TURN
credentials, no bytes when asking for them, and `bye: forbidden` for a live
view. A device credential stays bounded by its dashboards. The device page
sets it in its Camera section, and a tile the viewer may not see says
"No access to this camera" and asks the camera for nothing.

C3:
- A volatile upload is held to MAX_FRAME_BYTES (4 MiB, 413 above it, read
  without extra copies), and so is a frame on a device's socket.
- A frame the engine holds in memory is written to the ring directory
  before a local worker is handed it, so load_artifact finds it.
- A socket the bus dropped events for catches up with a snapshot, demand
  included, and a device's credential is checked again per frame, cached by
  the flow store revision and its nonce, so a lost event never keeps an
  unpaired device's frames coming.
- A report is at most 64 KB once its named config_schemas are put in place.
- A device away for 60 s has its true bool messages set to false.
- Refused frames are logged by fixed keys, a frame is named after its
  message, `fluksio serve` waits 5 s for open connections, a tile with a
  stream URL creates no demand, the 8-name cap keeps the newest names.
- Every container's log rotates (json-file, 3 x 10 MB).
2026-10-17 09:20:04 +02:00
Melvin Strobl 4286acadfd Capability report: PUT /devices/{id}/report, a Capabilities section, offline devices degraded
A device reports its board, screen, camera and ports from its own
credential (16 KB, schema 1, replacing the last report), and the flows
are validated against it again. The node panel turns a reported port's
config schema into a form, a reported screen is a canvas preset and a
touch screen's first report turns Touch friendly on. An offline device
node is degraded: amber on the canvas, a warning on Home, never a fault.
2026-10-16 17:37:49 +02:00
Melvin Strobl 29d3ec467f Device node: a device's ports are wired in flows
- flow/nodes/device.py: `device` node with params `device` and `config`;
  provides the device's `in` ports, requires its `out` ports without
  waking anything, never run (Node.passive), down "Offline" from presence
- DeviceDef.io and DevicePort go; GET /devices/{id} computes `io` and
  `bindings` from the device nodes of published flows, in a fixed order,
  cached by FlowStore.revision; the credential's scope comes from them
- issues `unknown_device` and `device_port` (wired twice; against a report
  the wrong direction or dtype, or unlisted as advisory), rechecked when a
  device is created or deleted; ValidationIssue.advisory is a field
- a device publishing on a bound port is credited to its node by the
  server; the panel endpoint kind is gone from `_endpoints` and the canvas
- a rebuild that moves a device's bindings sends `dashboard_changed` with
  an empty name, which the firmware refetches on
- startup moves each device's `io` rows into device nodes in the flows
  declaring their messages, draft and published, one commit; rows no
  flow declares are logged and left out
- frontend: Device node settings (device, Publishes, Follows, a port
  picker from a report), palette shortcuts per reported port, DeviceDetail
  lists bindings with "Use in flow" in place of the I/O editor
- docs: devices, flow editor, node types, issues, API
2026-10-16 16:40:31 +02:00